Southeast Aerospace will be closed December 23rd - January 3rd for the Holidays.
Regular business hours will resume on Monday, January 6th. AOG Services are available.

Picture of product CTL-92T

Part #:

Model: CTL-92T

OEM:

Collins Aerospace

Desc:

TCAS Control

Part Number :


CTL-92T

 

FEATURES

  • TCAS control used in conjunction with transponder control to provide ARINC 429 control of TDR-94D transponder and TCAS II System
  • Accepts mode A and mode C code from CTL-92, parallel code from CTL-90 or ARINC 429 code from compatible ARINC 429 controls
  • Adds TCAS control data to mode A and mode C code and outputs data via ARINC 429 output words for appropriate transponder
  • Models available with black or gray bezel (see table below)
  • Models available with 5 or 28 volt lighting (see table below)
  • Models available with variations of OFF-STBY-AUTO-TA ONLY switch selections (see table below)
  • Models available with variations of display control pushbuttons (see table below)
  • Models available with additional range selections for 40 and 3 nmi (see table below)

 

SPECIFICATIONS

Weight: 1.3 lbs. Dimensions: 2.395"W x 2.645"H x 6.83"L
TSO: C112, C119 EUROCAE: ED-14B (Env), ED-12A (software)
Input Power: 28VDC (16 to 32) at 7W max Lighting: 5V ac/dc blue-white lighting at 350Ma 28V dc blue-white lighting at 100Ma
Part Number TCAS Control Description:
622-9614-001 5V lighting, gray panel, no display control pushbuttons, STBY-AUTO-TA ONLY switch positions
622-9614-002 28V lighting, gray panel, no display control pushbuttons, STBY-AUTO-TA ONLY switch positions
622-9614-003 5V lighting, black panel, no display control pushbuttons, STBY-AUTO-TA ONLY switch positions
622-9614-004 28V lighting, black panel, no display control pushbuttons, STBY-AUTO-TA ONLY switch positions
622-9614-005 5V lighting, gray panel, M,A/B,R display control pushbuttons, STBY-AUTO-TA ONLY switch positions
622-9614-006 28V lighting, gray panel, M,A/B,R display control pushbuttons, STBY-AUTO-TA ONLY switch positions
622-9614-007 5V lighting, black panel, M,A/B,R display control pushbuttons, STBY-AUTO-TA ONLY switch positions
622-9614-008 28V lighting, gray panel, M,A/B,R display control pushbuttons, STBY-AUTO-TA ONLY switch positions
622-9614-009 5V lighting, gray panel, no display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions
622-9614-010 28V lighting, gray panel, no display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions
622-9614-011 5V lighting, black panel, no display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions
622-9614-012 28V lighting, black panel, no display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions
622-9614-013 5V lighting, gray panel, M,A/B,R display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions
622-9614-014 28V lighting, gray panel, M,A/B,R display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions
622-9614-015 5V lighting, black panel, M,A/B,R display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions
622-9614-016 28V lighting, black panel, M,A/B,R display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions
622-9614-101 5V lighting, gray panel, no display control pushbuttons, STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-102 28V lighting, gray panel, no display control pushbuttons, STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-103 5V lighting, black panel, no display control pushbuttons, STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-104 28V lighting, black panel, no display control pushbuttons, STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-105 5V lighting, gray panel, M,A/B,R display control pushbuttons, STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-106 28V lighting, gray panel, M,A/B,R display control pushbuttons, STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-107 5V lighting, black panel, M,A/B,R display control pushbuttons, STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-108 28V lighting, gray panel, M,A/B,R display control pushbuttons, STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-109 5V lighting, gray panel, no display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-110 28V lighting, gray panel, no display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-111 5V lighting, black panel, no display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-112 28V lighting, black panel, no display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-113 5V lighting, gray panel, M,A/B,R display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-114 28V lighting, gray panel, M,A/B,R display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-115 5V lighting, black panel, M,A/B,R display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi
622-9614-116 28V lighting, black panel, M,A/B,R display control pushbuttons, OFF-STBY-AUTO-TA ONLY switch positions, additional range selections of 40 and 3 nmi


PLEASE NOTE: THE ABOVE LISTED PART NUMBERS REFLECT THE DIFFERENT UNITS ORIGINALLY AVAILABLE BY THE MANUFACTURER AND DO NOT NECESSARILY INDICATE OR REFLECT THE CURRENT AVAILBILITY OF THESE DIFFERENT UNITS BY SOUTHEAST AEROSPACE OR THE AFTERMARKET

 

 

 

622-9614-112
- TCAS Control

NSN: 5895-01-588-0995

Price Condition Status
$1,450.00 OH OUTRIGHT 1 IN STOCK
$950.00 OH EXCHANGE 1 IN STOCK
REQUEST AR OUTRIGHT 1 IN STOCK
622-9614-001
- TCAS Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-9614-003
- TCAS Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-9614-009
- TCAS Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-9614-011
- TCAS Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-9614-103
- TCAS Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-9614-104
- TCAS Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-9614-105
- TCAS Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-9614-107
- TCAS Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-9614-111
- TCAS Control
Price Condition Status
REQUEST OH OUTRIGHT REQUEST LEAD TIME
REQUEST OH EXCHANGE REQUEST LEAD TIME
622-9614-116
- TCAS Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME

Click on a question below to see the answer. If you have a question about this model that is not answered below, please contact questions@seaerospace.com


In relation to NE (New) parts, many OEMs change their prices and availability without any notice to dealers or the industry. Therefore, through the REQUEST or RFQ indication, we ask that customers contact us for the most accurate price and availability.

In relation to SV & OH parts, the used parts aftermarket in the aviation industry is not an infinite supply. It is a dynamic, constantly changing market that is significantly affected by and susceptible to highs and lows in supply and demand. Therefore, although we attempt to, at times, we are unable to predict the exact moment when an item may be available. Once again, through the REQUEST or RFQ indication on our website, we ask that customers contact us for the most current and accurate price and availability.

"As Removed" or condition "AR" parts are in the same condition as they were removed from an aircraft. The reasons for removal include aircraft upgrades, teardowns, or certain types of incidents. In most cases, AR parts have not been inspected or tested. They do not include airworthiness certification such as FAA Form 8130 or EASA Form 1. Southeast Aerospace encourages avionics in this condition to be tested and recertified before using in an aircraft.