Southeast Aerospace will be closed December 23rd - January 3rd for the Holidays.
Regular business hours will resume on Monday, January 6th. AOG Services are available.

Picture of product CTL-30

Part #:

Model: CTL-30

OEM:

Collins Aerospace

Desc:

Nav Control

Part Number :


CTL-30

 

FEATURES

  • Digital Display Navigation Radio Control
  • Provides active and preset frequency display as well as mode selection
  • Self test feature
  • Typically used with VIR-30 series navigation receivers
  • Capable of simultaneously tuning a DME and NAV radio
  • Models available with transfer switch to switch control of DME between two NAV systems (see table below)
  • Models available with black or gray bezel (see table below)
  • Models available with 5 or 28 volt, clear white or blue-white lighting (see table below)
  • Models available with variations of NAV/DME power switch, Volume Control, DME Hold, DME Transfer, NORMAL/HOLD/NAV1/NAV2 selections (see table below)

 

SPECIFICATIONS

Weight: 1.4 lbs. Dimensions: 2.50"W x 3.125"H x 6.80"L
Related documents: FAA TSO C37b, C38b, C40a, C41c, C66a, C74c; RTCA DO-160 Env Cat. A2D1/B/PKS/EXXXXXZBAZZ ARINC Specification 410 Temperature: -20 to +70 C (operating)
Altitude: 51000 ft. max. Shock: 6 g for 11 ms
Explosion: Procedure I Electrical input: 24.8 to 30.3 V dc
Voltage spike: 600-V, 10-us spikes RF susceptibility: DO 160 paragraph 20.0
Af conducted susceptibility: DO 160 paragraph 18.1 Induced signal susceptibility: DO 160 paragraph 19.0
Emission of rf energy: DO 160 paragraph 21.0 Display type: Gas discharge
Display dim: Controlled by external 1 kohm potentiometer Tune outputs: Ground/open signal capable of sinking 100 mA dc
Channel Spacing: 50 kHz Frequency Range: 108.00-117.95 MHz
Part Number:  Description:
622-4524-041 5 Volt lighting, gray panel, NAV/DME selections, NO NAV/DME power switch, NO Volume Control, NO DME Hold, NO DME Transfer
622-4524-042 28 Volt lighting, gray panel, NAV/DME selections, NO NAV/DME power switch, NO Volume Control, NO DME Hold, NO DME Transfer
622-4524-043 5 Volt lighting, black panel, NAV/DME selections, NO NAV/DME power switch, NO Volume Control, NO DME Hold, NO DME Transfer
622-4524-044 28 Volt lighting, black panel, NAV/DME selections, NO NAV/DME power switch, NO Volume Control, NO DME Hold, NO DME Transfer
622-4524-049 5 Volt lighting, gray panel, OFF/NAV/DME/FREQ selections, NAV/DME power switch, NO Volume Control, NO DME Hold, NO DME Transfer
622-4524-050 28 Volt lighting, gray panel, OFF/NAV/DME/FREQ selections, NAV/DME power switch, NO Volume Control, NO DME Hold, NO DME Transfer
622-4524-051 5 Volt lighting, black panel, OFF/NAV/DME/FREQ selections, NAV/DME power switch, NO Volume Control, NO DME Hold, NO DME Transfer
622-4524-052 28 Volt lighting, black panel, OFF/NAV/DME/FREQ selections, NAV/DME power switch, NO Volume Control, NO DME Hold, NO DME Transfer
622-4524-053 5 Volt lighting, gray panel, NAV/DME selections, NO NAV/DME power switch, Volume Control, NO DME Hold, NO DME Transfer
622-4524-054 28 Volt lighting, gray panel, NAV/DME selections, NO NAV/DME power switch, Volume Control, NO DME Hold, NO DME Transfer
622-4524-055 5 Volt lighting, black panel, NAV/DME selections, NO NAV/DME power switch, Volume Control, NO DME Hold, NO DME Transfer
622-4524-056 28 Volt lighting, black panel, NAV/DME selections, NO NAV/DME power switch, Volume Control, NO DME Hold, NO DME Transfer
622-4524-057 5 Volt lighting, gray panel, OFF/NAV/DME selections, NAV power switch only, Volume Control, NO DME Hold, NO DME Transfer
622-4524-058 28 Volt lighting, gray panel, OFF/NAV/DME selections, NAV power switch only, Volume Control, NO DME Hold, NO DME Transfer
622-4524-059 5 Volt lighting, black panel, OFF/NAV/DME selections, NAV power switch only, Volume Control, NO DME Hold, NO DME Transfer
622-4524-060 28 Volt lighting, black panel, OFF/NAV/DME selections, NAV power switch only, Volume Control, NO DME Hold, NO DME Transfer
622-4524-061 5 Volt lighting, gray panel, OFF/NAV/DME/FREQ selections, NAV/DME power switch, Volume Control, NO DME Hold, NO DME Transfer
622-4524-062 28 Volt lighting, gray panel, OFF/NAV/DME/FREQ selections, NAV/DME power switch, Volume Control, NO DME Hold, NO DME Transfer
622-4524-063 5 Volt lighting, black panel, OFF/NAV/DME/FREQ selections, NAV/DME power switch, Volume Control, NO DME Hold, NO DME Transfer
622-4524-064 28 Volt lighting, black panel, OFF/NAV/DME/FREQ selections, NAV/DME power switch, Volume Control, NO DME Hold, NO DME Transfer
622-4524-065 5 Volt lighting, gray panel, NORM/HOLD/FREQ selections, NO NAV/DME power switch, NO Volume Control, DME Hold, NO DME Transfer
622-4524-066 28 Volt lighting, gray panel, NORM/HOLD/FREQ selections, NO NAV/DME power switch, NO Volume Control, DME Hold, NO DME Transfer
622-4524-067 5 Volt lighting, black panel, NORM/HOLD/FREQ selections, NO NAV/DME power switch, NO Volume Control, DME Hold, NO DME Transfer
622-4524-068 28V lighting, black panel, NORM/HOLD/FREQ selections, NO NAV/DME power switch, NO Volume Ctl, DME Hold, NO DME Transfer
622-4524-073 5V lighting, gray panel, OFF/NAV/DME/HOLD/FREQ selections, NAV/DME power switch, NO Volume Ctl, DME Hold, NO DME Transfer
622-4524-074 28V lighting, gray panel, OFF/NAV/DME/HOLD/FREQ selections, NAV/DME power switch, NO Volume Ctl, DME Hold, NO DME Transfer
622-4524-075 5V lighting, black panel, OFF/NAV/DME/HOLD/FREQ selections, NAV/DME power switch, NO Volume Ctl, DME Hold, NO DME Transfer
622-4524-076 28V lighting, black panel, OFF/NAV/DME/HOLD/FREQ selections, NAV/DME power switch, NO Volume Ctl, DME Hold, NO DME Transfer
622-4524-077 5 Volt lighting, gray panel, NORM/HOLD/FREQ selections, NO NAV/DME power switch, Volume Control, DME Hold, NO DME Transfer
622-4524-078 28 Volt lighting, gray panel, NORM/HOLD/FREQ selections, NO NAV/DME power switch, Volume Control, DME Hold, NO DME Transfer
622-4524-079 5 Volt lighting, black panel, NORM/HOLD/FREQ selections, NO NAV/DME power switch, Volume Control, DME Hold, NO DME Transfer
622-4524-080 28 Volt lighting, black panel, NORM/HOLD/FREQ selections, NO NAV/DME power switch, Volume Control, DME Hold, NO DME Transfer
622-4524-085 5 Volt lighting, gray panel, OFF/NAV/DME/HOLD/FREQ selections, NAV/DME power switch, Volume Control, DME Hold, NO DME Transfer
622-4524-086 28 Volt lighting, gray panel, OFF/NAV/DME/HOLD/FREQ selections, NAV/DME power switch, Volume Control, DME Hold, NO DME Transfer
622-4524-087 5 Volt lighting, black panel, OFF/NAV/DME/HOLD/FREQ selections, NAV/DME power switch, Volume Control, DME Hold, NO DME Transfer
622-4524-088 28 Volt lighting, black panel, OFF/NAV/DME/HOLD/FREQ selections, NAV/DME power switch, Volume Control, DME Hold, NO DME Transfer
622-4524-097 5 Volt lighting, gray panel, FREQ/NAV1/NAV2 selections, NO NAV/DME power switch, NO Volume Control, NO DME Hold, DME Transfer
622-4524-098 28 Volt lighting, gray panel, FREQ/NAV1/NAV2 selections, NO NAV/DME power switch, NO Volume Control, NO DME Hold, DME Transfer
622-4524-099 5 Volt lighting, black panel, FREQ/NAV1/NAV2 selections, NO NAV/DME power switch, NO Volume Control, NO DME Hold, DME Transfer
622-4524-100 28 Volt lighting, black panel, FREQ/NAV1/NAV2 selections, NO NAV/DME power switch, NO Volume Control, NO DME Hold, DME Transfer
622-4524-101 5 Volt lighting, gray panel, FREQ/NAV1/NAV2 selections, NO NAV/DME power switch, Volume Control, NO DME Hold, DME Transfer
622-4524-102 28 Volt lighting, gray panel, FREQ/NAV1/NAV2 selections, NO NAV/DME power switch, Volume Control, NO DME Hold, DME Transfer
622-4524-103 5 Volt lighting, black panel, FREQ/NAV1/NAV2 selections, NO NAV/DME power switch, Volume Control, NO DME Hold, DME Transfer
622-4524-104 28 Volt lighting, black panel, FREQ/NAV1/NAV2 selections, NO NAV/DME power switch, Volume Control, NO DME Hold, DME Transfer
622-4524-105 5V lighting, gray panel, FREQ/HOLD//NAV1/NAV2/HOLD selections, NO NAV/DME power switch, NO Volume Control, DME Hold, DME Transfer
622-4524-106 28V lighting, gray panel, FREQ/HOLD//NAV1/NAV2/HOLD selections, NO NAV/DME power switch, NO Volume Control, DME Hold, DME Transfer
622-4524-107 5V lighting, black panel, FREQ/HOLD//NAV1/NAV2/HOLD selections, NO NAV/DME power switch, NO Volume Control, DME Hold, DME Transfer
622-4524-108 28V lighting, black panel, FREQ/HOLD//NAV1/NAV2/HOLD selections, NO NAV/DME power switch, NO Volume Ctl, DME Hold, DME Transfer
622-4524-109 5 Volt lighting, gray panel, FREQ/HOLD//NAV1/NAV2/HOLD selections, NO NAV/DME power switch, Volume Control, DME Hold, DME Transfer
622-4524-110 28 Volt lighting, gray panel, FREQ/HOLD//NAV1/NAV2/HOLD selections, NO NAV/DME power switch, Volume Control, DME Hold, DME Transfer
622-4524-111 5 Volt lighting, black panel, FREQ/HOLD//NAV1/NAV2/HOLD selections, NO NAV/DME power switch, Volume Control, DME Hold, DME Transfer
622-4524-112 28 Volt lighting, black panel, FREQ/HOLD//NAV1/NAV2/HOLD selections, NO NAV/DME power switch, Volume Control, DME Hold, DME Transfer
622-4524-277 5 Volt lighting, gray panel, OFF/NAV/DME selections, NAV power switch only, Volume Control, NO DME Hold, NO DME Transfer, blue-white lighting instead of standard clear white lighting
622-4524-278 28 Volt lighting, black panel, OFF/NAV/DME selections, NAV power switch only, Volume Control, NO DME Hold, NO DME Transfer, blue-white lighting instead of standard clear white lighting
622-4524-279 5 Volt lighting, gray panel, OFF/NAV/DME/HOLD/FREQ selections, NAV/DME power switch, Volume Control, DME Hold, NO DME Transfer, blue-white lighting instead of standard clear white lighting


PLEASE NOTE: THE ABOVE LISTED PART NUMBERS REFLECT THE DIFFERENT UNITS ORIGINALLY AVAILABLE BY THE MANUFACTURER AND DO NOT NECESSARILY INDICATE OR REFLECT THE CURRENT AVAILBILITY OF THESE DIFFERENT UNITS BY SOUTHEAST AEROSPACE OR THE AFTERMARKET

 

622-4524-086
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT IN WORK
622-4524-057
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-058
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-059
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-060
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-061
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-062
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-063
- Nav Control

NSN: 5826-01-448-0869

Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-064
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-085
- Nav Control
Price Condition Status
$2,500.00 SV OUTRIGHT REQUEST LEAD TIME
622-4524-087
- Nav Control

NSN: 5826-01-309-9753

Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-088
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME
622-4524-278
- Nav Control
Price Condition Status
REQUEST SV OUTRIGHT REQUEST LEAD TIME

Click on a question below to see the answer. If you have a question about this model that is not answered below, please contact questions@seaerospace.com


In relation to NE (New) parts, many OEMs change their prices and availability without any notice to dealers or the industry. Therefore, through the REQUEST or RFQ indication, we ask that customers contact us for the most accurate price and availability.

In relation to SV & OH parts, the used parts aftermarket in the aviation industry is not an infinite supply. It is a dynamic, constantly changing market that is significantly affected by and susceptible to highs and lows in supply and demand. Therefore, although we attempt to, at times, we are unable to predict the exact moment when an item may be available. Once again, through the REQUEST or RFQ indication on our website, we ask that customers contact us for the most current and accurate price and availability.

The CTL-X0 is 30-40 years old. Service parts from Collins are either no longer available or extremely expensive. It is not cost effective nor possible in some situations to continue to utilize the CTL-X0 controls in your aircraft. Southeast Aerospace recommends converting the CTL-X0 controls over to the Collins CTL-X2 Proline II controls.

The CTL-X2 is not a direct replacement for the CTL-X0 controls. A connector change, CAD adapter, and locally fabricated panel filler plate are required for the change. A qualified avionics technician should perform this modification. While this is a moderately involved retrofit, it is a change that is eminent and will ultimately be required if you continue to use your original Proline I radios.

  • To convert from the CTL-20 Comm control, the CTL-22, CAD-31, mating connectors, and CAD bracket are required.
  • To convert from the CTL-30 Nav control, the CTL-32, CAD-31, mating connectors, and CAD bracket are required.
  • To convert from the CTL-60 ADF control, the CTL-62, CAD-62, mating connectors, and CAD bracket are required.
  • To convert from the CTL-90 Transponder control, the CTL-92, CAD-62, mating connectors, and CAD bracket are required.

For an exact SEA quote to convert from your CTL-X0 control, please provide the part number of your CTL-X0. Contact SEA with this information and an SEA rep will provide a quotation immediately.

Most of the Collins Proline I components were originally manufactured in the early 1970s. Collins has continued to produce some of the Proline I components by special order over the past 30 years however large scale production stopped many years ago. Most of the Collins Proline I product lines incorporates 1960s and 70s analog technology. Collins has superseded the Proline I product line several times with the Proline II, Proline IV, and Proline 21 lines. As a result, some service parts needed to maintain and repair original Collins Proline I components are no longer available. Therefore, you may experience limited to no warranty available and unreliability for many of the Proline I units.

Southeast Aerospace offers many affordable, upgradeable options that are available for aircraft with Collins Proline I. As avionics integration specialists and premiere Collins dealer, Southeast Aerospace is experienced and knowledgeable on all Collins Proline generations.

If you are interested in upgrading any of your original Collins Proline I systems, please contact us for the most reasonable, optimal choice available.